Products

Techflo qt Standard 2.3 bar Single - Shower & whole house pumps

Previous Products

The Techflo qt Standard 2.3 bar Single pump has been phased out and superseded by the equivalent Monsoon pump (for a whole house) or Showermate pump (for a single shower/bathroom).

For whole house applications, see Monsoon S3.0 bar Single

For single shower/bathroom applications, see Showermate S2.6 bar Single

 

 

Techflo qt Standard Single pumps are designed to improve water supplies to single taps or to pump blended water from a shower mixer. Suitable for positive head applications only.

Standard pumps require a flow of 1.0 l/min through the outlet to start.

Application

  • Boost the water pressure in either the hot or cold supply

Technical Specification

General
Product code 49078
Guarantee 3 years
WRAS approval 1406331
Features
Pump type Centrifugal
Mechanical seal Nitrile / Carbon / Silicon Carbide
Anti vibration feet  
Inlet strainer(s)  
Flexible hoses 2
Dry run protection  
Performance
Maximum head (closed valve) 2.3 bar
Performance @ 9 l/min 1.7 bar
Performance @ 18 l/min 1.3 bar
Maximum flow 32 l/min
Maximum static inlet pressure 6 metres
Maximum working pressure* 460 kPa (4.6 bar)
Maximum ambient air temperature 40 °C
Min / Max water temperature** Min 4 °C / Max 65 °C
Flow switch sensitivity (approx) 1.0 l/min
Connections
Pump connections 22 mm male
Flexible hoses
Connections 22 mm female x 22 mm push-in
200 mm long
isolating valves on inlet hose
Motor
Type Induction, auto-reset thermal trip
Duty rating Intermittent, 30 mins on, 30 mins off @ 20 l/min
Electrical
Power supply/phase/frequency 230 V a.c./ 1 / 50 Hz
Current (full load) 1.2 Amps
Power consumption 290 Watts
Fuse rating 5 Amps
Power cable (pre-wired) 1.5 metres
Physical
Enclosure protection IPX2
Length 322 mm
Width 134 mm
Height (excluding hoses) 220 mm
Weight (including fittings) 5.6 Kg


* The maximum pressure that can be applied to the pump under any installation conditions.

** A stored water temperature of 60 °C is considered sufficient to meet all normal requirements and will minimise deposition of scale in hard water areas.