MAINSBOOST

MAINSBOOST MB 250SV

Find a Local Stockist

Find an Online Stockist

Mains Water Boosting System

The MAINSBOOST MB 250SV-1 is designed for 'direct on mains' systems (unvented hot water cylinders and combination boilers) where the incoming mains pressure is greater than 2.5 bar but the flow is insufficient to meet demand.
MAINSBOOST vessel systems do not require an electrical supply and operate silently.

System cold water storage capacity can be expanded simply by adding one or more MAINSBOOST Add-on units as required. 
If the incoming mains water pressure is less than 2.5 bar, a MAINSBOOST Charger pump can be used in conjunction with the MAINSBOOST vessel system to boost pressure.

The MAINSBOOST MB 250SV-1 features a nominal vessel size of 250 litres and a pressurised cold water water storage capacity of approximately 137 litres.
Each unit is supplied with the unique compact MAINSBOOST Monobloc 22/28mm Upstream Kit (USK) as standard which significantly simplifies installation.

Constructed from an epoxy coated steel body and a highly durable virgin butyl diaphragm, all MAINSBOOST vessels are supplied with a 5 year warranty.

5 Year Warranty UKCA-CE
Mainsboost  MB 250SV-1-22
Key Features
  • 5 year warranty
  • Up to 80 litres/minute per vessel
  • 1 x 250 litre pressure vessel
Technical Specification
Product Code 44461
GENERAL
GTIN 5050400444619
Warranty 5 years
Conformity certification UKCA | CE
FEATURES
Pressure vessel nominal size 250 litres
Pressure vessel quantity 1
Pressure vessel usable capacity** 137.5 litres
Upstream kit Monobloc 22/28 mm
Mounting Floor
PERFORMANCE
Maximum working pressure* 1000 kPa (10 bar)
Min / Max operating temperature Min 4 °C / Max 35 °C
Max rated temperature 90 °C
Typical noise Silent
CONSTRUCTION
Pressure vessel Epoxy coated mild steel
Membrane Butyl rubber
CONNECTIONS
Connection - inlet 22 mm
Connection - outlet 22 mm
DIMENSIONS
Width 535 mm
Depth 535 mm
Height 1210 mm
Weight - including fittings 40.7 Kg
Weight - filled 178.2 Kg
Weight - maximum*** 290.7 Kg
* The maximum pressure that can be applied to the cylinder under any installation conditions.
** At typical working pressure.
*** The maximum weight of the vessel under fault conditions